Table of Contents

Advertisement

COPIER > DISPLAY > HT-C
SGL-B-M2
ARCDAT scrnB M-patch current VL(1/2 SPD)
Lv.2 Details
To display the current M-patch value of screen B in ARCDAT control
at 1/2 speed.
When hue variation occurs and the value shown is not in the
tolerable range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
SGL-B-C2
ARCDAT scrnB C-patch current VL(1/2 SPD)
Lv.2 Details
To display the current C-patch value of screen B in ARCDAT control
at 1/2 speed.
When hue variation occurs and the value shown is not in the
tolerable range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
SGL-B-K2
ARCDAT scrnB Bk-patch current VL(1/2SPD)
Lv.2 Details
To display the current Bk-patch value of screen B in ARCDAT control
at 1/2 speed.
When hue variation occurs and the value shown is not in the
tolerable range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
SGL-C-Y2
ARCDAT scrnC Y-patch current VL(1/2 SPD)
Lv.2 Details
To display the current Y-patch value of screen C in ARCDAT control
at 1/2 speed.
When hue variation occurs and the value shown is not in the
tolerable range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
SGL-C-M2
ARCDAT scrnC M-patch current VL(1/2 SPD)
Lv.2 Details
To display the current M-patch value of screen C in ARCDAT control
at 1/2 speed.
When hue variation occurs and the value shown is not in the
tolerable range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
SGL-C-C2
ARCDAT scrnC C-patch current VL(1/2 SPD)
Lv.2 Details
To display the current C-patch value of screen C in ARCDAT control
at 1/2 speed.
When hue variation occurs and the value shown is not in the
tolerable range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
8
Service Mode > COPIER > DISPLAY > HT-C
8
Service Mode > COPIER > DISPLAY > HT-C
COPIER > DISPLAY > HT-C
SGL-C-K2
ARCDAT scrnC Bk-patch current VL(1/2SPD)
Lv.2 Details
To display the current Bk-patch value of screen C in ARCDAT control
at 1/2 speed.
When hue variation occurs and the value shown is not in the
tolerable range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Display/adj/set range
0 to 1023
SUM-A-Y3
ARCDAT scrnA Y-clr ctrl differ (1/3 SPD)
Lv.2 Details
To display Y-patch control difference of screen A in ARCDAT control
at 1/3 speed.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
SUM-A-M3
ARCDAT scrnA M-clr ctrl differ (1/3 SPD)
Lv.2 Details
To display M-patch control difference of screen A in ARCDAT control
at 1/3 speed.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
SUM-A-C3
ARCDAT scrnA C-clr ctrl differ (1/3 SPD)
Lv.2 Details
To display C-patch control difference of screen A in ARCDAT control
at 1/3 speed.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
SUM-A-K3
ARCDAT scrnA Bk-clr ctrl differ(1/3 SPD)
Lv.2 Details
To display Bk-patch control difference of screen A in ARCDAT control
at 1/3 speed.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023