Canon imageRUNNER ADVANCE C5255 Series Service Manual page 902

Hide thumbs Also See for imageRUNNER ADVANCE C5255 Series:
Table of Contents

Advertisement

COPIER > ADJUST > CCD
MTF-M10
MTF value 10 setting: horz scan [Back]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
- When replacing the Scanner Unit
- When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 85
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF-M11
MTF value 11 setting: horz scan [Back]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
- When replacing the Scanner Unit
- When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 85
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF-M12
MTF value 12 setting: horz scan [Back]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
- When replacing the Scanner Unit
- When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 85
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF-S10
MTF value 10 setting: vert scan [Back]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
- When replacing the Scanner Unit
- When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 85
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
8
Service Mode > COPIER > ADJUST > CCD
8
Service Mode > COPIER > ADJUST > CCD
COPIER > ADJUST > CCD
MTF-S11
MTF value 11 setting: vert scan [Back]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
- When replacing the Scanner Unit
- When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 85
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF-S12
MTF value 12 setting: vert scan [Back]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
- When replacing the Scanner Unit
- When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 85
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
DFCH2K2
Complex chart No.2 data (B&W) [Front]
Lv.1 Details
To derive the front/back side linearity, set the B&W data (for paper
front) of No.2 image in DADF complex chart.
Enter the value of service label on the Reader.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
1 to 2550
Default value
2000
DFCH2K10
Complex chart No.10 data (B&W) [Front]
Lv.1 Details
To derive the front/back side linearity, set the B&W data (for paper
front) of No.10 image in DADF complex chart.
Enter the value of service label on the Reader.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 2550
Default value
0
8-82
8-82

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents