[:Source<N>]:Voltage[:Level][:Immediate]:Offset - Rigol MSO2000A Series Programming Manual

Digital oscilloscope
Hide thumbs Also See for MSO2000A Series:
Table of Contents

Advertisement

2 Command System
[:SOURce<n>]:VOLTage[:LEVel][:IMMediate]:OFFSet
Syntax
[:SOURce<n>]:VOLTage[:LEVel][:IMMediate]:OFFSet {<offset>|MINimum|MAXimum}
[:SOURce<n>]:VOLTage[:LEVel][:IMMediate]:OFFSet? [MINimum|MAXimum]
Description
Set or query the DC offset of the waveform currently selected. The default unit is VDC.
Parameter
Name
Type
[1]
<offset>
Real
<n>
Discrete
Explanation
You can use the
[:SOURce<n>]:VOLTage[:LEVel][:IMMediate][:AMPLitude]
amplitude of the waveform currently selected and use the
set the output impedance of the signal source.
When the current waveform is DC, the offset range is from -2.5VDC to 2.5VDC.
Return Format
The query returns the current offset in scientific notation.
MSO2000A/DS2000A Programming Guide
Range
HighZ: -2.5+current amplitude/2 to
2.5- current amplitude /2
50Ω: -1.25+ current amplitude /2 to
1.25- current amplitude /2
{1|2}
Default
0VDC
1
command to set the
:OUTPut[<n>]:IMPedance
RIGOL
command to
2-229

Hide quick links: