:SAVE:MTESt[:STARt]

Syntax
:SAVE:MTESt[:STARt] {<internal_loc>|<file_spec>}
Description
Store the current pass/fail test mask into the internal or external memory in "*.pf" format.
Parameter
Name
Type
<internal_loc>
ASCII string
<file_spec>
ASCII string
Explanation
This command is only available when the pass/fail test function is enabled (refer to :MASK:ENABle).
In internal storage, if the specified location already contains a file, the original file will be overwritten.
In external storage, <file_ spec> includes the external storage directory and the filename with suffix.
Its length cannot exceeds 64 characters. Wherein, the storage directory can only be D:\. If the
specified directory already contains a file with the same filename, the original file will be overwritten.
Example
:SAVE:MTESt C:\LocalPF3.pf /*Store the current pass/fail test mask into the internal memory*/
MSO2000A/DS2000A Programming Guide
Range
C:\LocalPF0 to C:\LocalPF9
Refer to the Explanation
RIGOL
Default
--
--
2-221