Rigol MSO2000A Series Programming Manual page 112

Digital oscilloscope
Hide thumbs Also See for MSO2000A Series:
Table of Contents

Advertisement

RIGOL
:FUNCtion:WRECord:FMAX?
Syntax
:FUNCtion:WRECord:FMAX?
Description
Query the maximum number of frames that can be recorded currently.
Explanation
You can use the
:FUNCtion:WRECord:FEND
The maximum number of frames that can be recorded currently depends on the current memory depth
(refer to the
:ACQuire:MDEPth
Memory Depth
Auto
14k points
140k points
1.4M points
14M points
56M points (option)
Return Format
The query returns the maximum number of frames that can be recorded in integer.
:FUNCtion:WRECord:INTerval
Syntax
:FUNCtion:WRECord:INTerval <interval>
:FUNCtion:WRECord:INTerval?
Description
Set or query the time interval between frames in waveform recording and the unit is s.
Parameter
Name
Type
<interval>
Real
Return Format
The query returns the current time interval in scientific notation.
2-96
command to set the desired end frame.
command).
Maximum End Frame
65000
8128
508
63
7
2
Range
100ns to 10s
Default
100ns
MSO2000A/DS2000A Programming Guide