[:SOURce<n>]:VOLTage[:LEVel][:IMMediate][:AMPLitude]
Syntax
[:SOURce<n>]:VOLTage[:LEVel][:IMMediate][:AMPLitude] {<amplitude>|MINimum|MAXimum}
[:SOURce<n>]:VOLTage[:LEVel][:IMMediate][:AMPLitude]? [MINimum|MAXimum]
Description
Set or query the amplitude of the waveform currently selected. The default unit is Vpp.
Parameter
Name
Type
<amplitude>
Real
<n>
Discrete
Explanation
You can use
:OUTPut[<n>]:IMPedance
Return Format
The query returns the current amplitude in scientific notation.
2-228
Range
HighZ: 20mVpp to 5Vpp
50Ω: 10mVpp to 2.5Vpp
{1|2}
command to set the output impedance of the signal source.
2 Command System
Default
5Vpp