RIGOL

:MEASure:PVRMs

Syntax 1
:MEASure:PVRMs <chan>
Description 1
Enable the RMS value measurement function within a single period of the specified channel.
Syntax 2
:MEASure:PVRMs? <chan>
Description 2
Enable the RMS value measurement function within a single period of the specified channel and return
the measurement result.
Parameter
Name
Type
<chan>
Discrete
Explanation
The unit is determined by the unit selected for the source channel (refer to the
command).
Return Format
The query returns the measurement result in scientific notation.
Example
:MEASure:PVRMs CHANnel1
:MEASure:PVRMs? CHANnel1
You can use the following commands to query the statistic maximum, minimum, current value, average
and standard deviation of the RMS value measurement values within a single period of the specified
channel. Sending the following commands will enable the statistic function automatically.
:MEASure:PVRMs:SMAXimum?
:MEASure:PVRMs:SMINimum?
:MEASure:PVRMs:SCURrent?
:MEASure:PVRMs:SAVerage?
:MEASure:PVRMs:SDEViation?
2-196
Range
{CHANnel1|CHANnel2|MATH}
2 Command System
Default
--
:CHANnel<n>:UNITs