2 Command System

:MASK:CREate

Syntax
:MASK:CREate
Description
Create the mask of the pass/fail test using the horizontal adjustment parameter and the vertical
adjustment parameter currently set.
Explanation
This command is valid only when the pass/fail test function is enabled (:MASK:ENABle) and is in
running state (:MASK:OPERate).
For the setting of the horizontal adjustment parameter, refer to the
setting of the vertical adjustment parameter, refer to the

:MASK:PASSed?

Syntax
:MASK:PASSed?
Description
Query the number of frames that pass the pass/fail test.
Return Format
The query returns an integer.

:MASK:FAILed?

Syntax
:MASK:FAILed?
Description
Query the number of failed frames in the pass/fail test.
Return Format
The query returns an integer.