2 Command System
SINusoid: sine
SQUare: square
USER: arbitrary waveform
<freq>: set the frequency of the specified waveform (noise does not have this parameter). The
default unit is Hz.
<amp>: set the amplitude of the specified waveform. The default unit is Vpp.
<offset>: set the DC offset of the specified waveform. The default unit is VDC.
<phase>: set the start phase of the specified waveform (noise does not have this parameter). The
default unit is degree (°).
One or more parameters can be omitted for these commands. When all the parameters are omitted,
these commands only configure the specified signal source channel to the specified waveform and
do not modify the corresponding parameters.
<freq>, <amp>, <offset> and <phase> are placed in order. You cannot omit the one parameter and
directly set the parameters behind it. For example, you cannot omit <freq> and directly set <amp>.
The ranges of <amp> and <offset> are related to the output impedance of the signal source
channel. You can use the
signal source.
Example
:APPLy:NOISe
:APPLy:PULSe 100,1,0.5
:SOURce2:APPLy:SINusoid 100,1,0.5,0 /*Set Source2 to output a sine with 100Hz frequency, 1Vpp
MSO2000A/DS2000A Programming Guide
:OUTPut[<n>]:IMPedance
/*Set the waveform of Source1 to noise and do not modify the
parameters*/
/*Set Source1 to output a pulse with 100Hz frequency, 1Vpp
amplitude and 500mVDC offset*/
amplitude, 500mVDC offset and 0° start phase*/