Measure:r2Fdelay - Rigol MSO2000A Series Programming Manual

Digital oscilloscope
Hide thumbs Also See for MSO2000A Series:
Table of Contents

Advertisement

RIGOL

:MEASure:R2FDeLay

Syntax1
:MEASure:R2FDeLay <chanA>,<chanB>
Description1
Enable the delay measurement function (rising edge-falling edge) between the two specified channels.
Syntax2
:MEASure:R2FDeLay? <chanA>,<chanB>
Description2
Enable the delay measurement function (rising edge-falling edge) between the two specified channels
and return the measurement result (the unit is s).
Parameter
Name
Type
<chanA>
Discrete
<chanB>
Discrete
Return Format
The query returns the measurement result in scientific notation.
Example
:MEASure:R2FDeLay CHANnel1,CHANnel2
:MEASure:R2FDeLay? CHANnel1,CHANnel2
You can use the following commands to query the statistic maximum, minimum, current value, average
and standard deviation of the delay measurement (rising edge-falling edge) results. Sending the following
commands will enable the statistic function automatically.
:MEASure:R2FDeLay:SMAXimum?
:MEASure:R2FDeLay:SMINimum?
:MEASure:R2FDeLay:SCURrent?
:MEASure:R2FDeLay:SAVerage?
:MEASure:R2FDeLay:SDEViation?
2-176
Range
{D0|D1|D2|D3|D4|D5|D6|D7|D8|D9|D10|D11|
D12|D13|D14|D15|CHANnel1|CHANnel2}
When <chanA> is D0-D15:
{D0|D1|D2|D3|D4|D5|D6|D7|D8|D9|D10|D11|D12|D13|D14|
D15}
When <chanA> is CHANnel1 or CHANnel2:
{CHANnel1|CHANnel2}
2 Command System
MSO2000A/DS2000A Programming Guide
Default
--
--

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents