2 Command System
[:SOURce<n>]:MOD[:STATe]
Syntax
[:SOURce<n>]:MOD[:STATe] <bool>
[:SOURce<n>]:MOD[:STATe]?
Description
Enable or disable the modulation function; or query the status of the modulation function.
Parameter
Name
Type
<bool>
Bool
<n>
Discrete
Explanation
The signal source of MSO2000A/DS2000A supports AM (Amplitude Modulation) and FM (Frequency
Modulation). You can send the
Sine, square, ramp, built-in waveform and arbitrary waveform (except DC) can be used as carrier
waveform.
Sine, square, triangle waveform or noise can be used as modulating waveform. You can use the
[:SOURce<n>]:MOD:AM:INTernal:FUNCtion
command to select the modulating waveform.
Return Format
The query returns 0 or 1.
MSO2000A/DS2000A Programming Guide
Range
{{0|OFF}|{1|ON}}
{1|2}
[:SOURce<n>]:MOD:TYPe
or
[:SOURce<n>]:MOD:FM:INTernal:FUNCtion
Default
0|OFF
1
command to set the modulation type.