RIGOL
:CALCulate:FFT:WINDow
Syntax
:CALCulate:FFT:WINDow <window>
:CALCulate:FFT:WINDow?
Description
Set or query the window function of the FFT operation.
Parameter
Name
Type
<window>
Discrete
Explanation
The window function can effectively reduce the spectrum leakage effect.
Different window function is suitable for measuring different waveform; therefore, please select the
desired window function according to the waveform to be measured and its characteristics.
Return Format
The query returns RECT, HANN, HAMM or BLAC.
:CALCulate:FFT:SPLit
Syntax
:CALCulate:FFT:SPLit <bool>
:CALCulate:FFT:SPLit?
Description
Enable or disable the split display of the FFT operation; or query the current status of the split display of
the FFT operation.
Parameter
Name
Type
<bool>
Bool
Explanation
ON: the source channel waveform and the FFT operation results are displayed separately. The time
domain and frequency domain signals are displayed clearly.
OFF (Full Screen): the source channel waveform and the FFT operation results are displayed in the
same window to view the frequency spectrum more clearly and to perform more precise
measurement.
Return Format
The query returns 0 or 1.
2-52
Range
{RECTangle|HANNing|HAMMing|BLACkman}
Range
{{0|OFF}|{1|ON}}
2 Command System
Default
RECTangle
Default
1|ON