:MASK:OUTPut

Syntax
:MASK:OUTPut <type>
:MASK:OUTPut?
Description
Set or query the output mode when the test fails.
Parameter
Name
Type
<type>
Discrete
Explanation
FAIL: when a failed waveform is detected, the oscilloscope displays the statistic results and outputs a
pulse; but the beeper does not sound.
FSOund: when a failed waveform is detected, the oscilloscope displays the statistic results and
outputs a pulse; while at the same time, the beeper sounds (not related to the on/off state of the
sound).
Return Format
The query returns FAIL or FSO.

:MASK:X

:MASK:Y

Syntax
:MASK:X <x>
:MASK:X?
:MASK:Y <y>
:MASK:Y?
Description
Set or query the horizontal or vertical adjustment parameter of the pass/fail test mask.
Parameter
Name
Type
<x>
Real
<y>
Real
Return Format
The query returns the current parameter in scientific notation.
2-130
Range
{FAIL|FSOund}
Range
0.02 to 4, the step is
0.02
0.04 to 5.12, the step is 0.04
2 Command System
Default
FAIL
Default
0.24
0.48