Rigol MSO2000A Series Programming Manual page 301

Digital oscilloscope
Hide thumbs Also See for MSO2000A Series:
Table of Contents

Advertisement

2 Command System
:TRIGger:NEDGe:LEVel
Syntax
:TRIGger:NEDGe:LEVel <level>
:TRIGger:NEDGe:LEVel?
Description
Set or query the trigger level in Nth edge trigger. The unit is the same with the current amplitude unit.
Parameter
Name
Type
<level>
Real
Note: For the VerticalScale, refer to the
the
:CHANnel<n>:OFFSet
Return Format
The query returns the trigger level in scientific notation.
:TRIGger:NEDGe:SLOPe
Syntax
:TRIGger:NEDGe:SLOPe <slope>
:TRIGger:NEDGe:SLOPe?
Description
Set or query the edge type of Nth edge trigger.
Parameter
Name
Type
<slope>
Discrete
Return Format
The query returns POSitive or NEGative.
MSO2000A/DS2000A Programming Guide
Range
When the trigger source is CHANnel1 or CHANnel2:
-5×VerticalScale–OFFSet to +5×VerticalScale–OFFSet
When the trigger source is any of D0-D15: -20V to 20V
:CHANnel<n>:SCALe
command.
Range
{POSitive|NEGative}
command. For the OFFSet, refer to
RIGOL
Default
0
Default
POSitive
2-285