RIGOL

:MEASure:VPP

Syntax 1
:MEASure:VPP <chan>
Description 1
Enable the peak-peak value measurement function of the specified channel.
Syntax 2
:MEASure:VPP? <chan>
Description 2
Enable the peak-peak value measurement function of the specified channel and return the measurement
result.
Parameter
Name
Type
<chan>
Discrete
Explanation
The unit is determined by the unit selected for the source channel (refer to the
command).
Return Format
The query returns the measurement result in scientific notation.
Example
:MEASure:VPP CHANnel1
:MEASure:VPP? CHANnel1
You can use the following commands to query the statistic maximum, minimum, current value, average
and standard deviation of the peak-peak measurement values of the specified channel waveform.
Sending the following commands will enable the statistic function automatically.
:MEASure:VPP:SMAXimum?
:MEASure:VPP:SMINimum?
:MEASure:VPP:SCURrent?
:MEASure:VPP:SAVerage?
:MEASure:VPP:SDEViation?
2-192
Range
{CHANnel1|CHANnel2|MATH}
Default
--
:CHANnel<n>:UNITs
MSO2000A/DS2000A Programming Guide
2 Command System