2 Command System
:TRIGger:VIDeo:LINE
Syntax
:TRIGger:VIDeo:LINE <line>
:TRIGger:VIDeo:LINE?
Description
Set or query the line number in video trigger when the sync type is Line Number (refer
to
:TRIGger:VIDeo:MODE
Parameter
Name
Type
<line>
Integer
Return Format
The query returns an integer.
MSO2000A/DS2000A Programming Guide
command).
Range
NTSC: 1 to 525
PAL: 1 to 625
480P: 1 to 525
576P: 1 to 625
720P60HZ: 1 to 750
720P50HZ: 1 to 750
720P30HZ: 1 to 750
720P25HZ: 1 to 750
720P24HZ: 1 to 750
1080P60HZ: 1 to 1125
1080P50HZ: 1 to 1125
1080P30HZ: 1 to 1125
1080P25HZ: 1 to 1125
1080P24HZ: 1 to 1125
1080I30HZ: 1 to 1125
1080I25HZ: 1 to 1125
1080I24HZ: 1 to 1125
Default
1