Rigol MSO2000A Series Programming Manual page 330

Digital oscilloscope
Hide thumbs Also See for MSO2000A Series:
Table of Contents

Advertisement

RIGOL
:TRIGger:SPI:SLOPe
Syntax
:TRIGger:SPI:SLOPe <slope>
:TRIGger:SPI:SLOPe?
Description
Set or query the edge type of the clock signal in SPI trigger.
Parameter
Name
Type
<slope>
Discrete
Return Format
The query returns POS or NEG.
:TRIGger:SPI:TIMeout
Syntax
:TRIGger:SPI:TIMeout <time_value>
:TRIGger:SPI:TIMeout?
Description
Set or query the timeout time in SPI trigger when the trigger condition is Timeout. The unit is s.
Parameter
Name
Type
<time_value>
Real
Return Format
The query returns the timeout time in scientific notation.
2-314
Range
{POSitive|NEGative}
Range
100ns to 1s
Default
POSitive
Default
1us