Rigol MSO2000A Series Programming Manual page 307

Digital oscilloscope
Hide thumbs Also See for MSO2000A Series:
Table of Contents

Advertisement

2 Command System
:TRIGger:PULSe:LWIDth
Syntax
:TRIGger:PULSe:LWIDth <width>
:TRIGger:PULSe:LWIDth?
Description
Set or query the lower limit of the pulse width in pulse trigger. The unit is s.
Parameter
Name
Type
<width>
Real
Explanation
This command is available when the trigger condition (refer to
PGReater (
), NGReater (
Return Format
The query returns the lower limit of the pulse width in scientific notation.
:TRIGger:PULSe:SOURce
Syntax
:TRIGger:PULSe:SOURce <source>
:TRIGger:PULSe:SOURce?
Description
Set or query the trigger source in pulse trigger.
Parameter
Name
Type
<source>
Discrete
Return Format
The query returns D0, D1, D2, D3, D4, D5, D6, D7, D8, D9, D10, D11, D12, D13, D14, D15, CHAN1,
CHAN2 or EXT.
MSO2000A/DS2000A Programming Guide
Range
and
and
), PGLess (
Range
{D0|D1|D2|D3|D4|D5|D6|D7|D8|D9|D10|
D11|D12|D13|D14|D15|CHANnel1|CHANnel2|EXT}
: 2ns to 4s
: 2ns to 3.99s
:TRIGger:PULSe:WHEN
) or NGLess (
Default
1us
command) is
).
Default
CHANnel1
RIGOL
2-291

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents