2 Command System
:MEASure:VRMS:SMAXimum?
:MEASure:VRMS:SMINimum?
:MEASure:VRMS:SCURrent?
:MEASure:VRMS:SAVerage?
:MEASure:VRMS:SDEViation?
Syntax 1
:MEASure:VRMS:SMAXimum <chan>
:MEASure:VRMS:SMINimum <chan>
:MEASure:VRMS:SCURrent <chan>
:MEASure:VRMS:SAVerage <chan>
:MEASure:VRMS:SDEViation <chan>
Description 1
Enable the RMS value measurement function on the whole signal of the specified channel and enable the
statistic function.
Syntax 2
:MEASure:VRMS:SMAXimum? <chan>
:MEASure:VRMS:SMINimum? <chan>
:MEASure:VRMS:SCURrent? <chan>
:MEASure:VRMS:SAVerage? <chan>
:MEASure:VRMS:SDEViation? <chan>
Description 2
Enable the amplitude RMS value measurement function on the whole signal of the specified channel;
enable the statistic function; return the maximum value, minimum value, current value, average value or
standard deviation.
Parameter
Name
Type
<chan>
Discrete
Explanation
The unit is determined by the unit selected for the source channel (refer to the
command).
Return Format
The query returns the measurement result in scientific notation.
MSO2000A/DS2000A Programming Guide
Range
{CHANnel1|CHANnel2|MATH}
Default
--
:CHANnel<n>:UNITs
RIGOL