RIGOL
[:SOURce[<n>]]:FUNCtion:RAMP:SYMMetry
Syntax
[:SOURce[<n>]]:FUNCtion:RAMP:SYMMetry <val>
[:SOURce[<n>]]:FUNCtion:RAMP:SYMMetry?
Description
Set or query the ramp symmetry (the percentage that the rising period takes up in the
whole period) of the specified source channel. The default unit is %.
Parameter
Name
[<n>]
<val>
Return
The query returns the symmetry in scientific notation, such as 5.000000e+01.
Format
Example
:FUNCtion:RAMP:SYMMetry 50
Related
[:SOURce[<n>]]:FUNCtion[:SHAPe]
Command
[:SOURce[<n>]]:VOLTage[:LEVel][:IMMediate][:AMPLitude]
Syntax
[:SOURce[<n>]]:VOLTage[:LEVel][:IMMediate][:AMPLitude] <Amplitude>
[:SOURce[<n>]]:VOLTage[:LEVel][:IMMediate][:AMPLitude]?
Description
Set or query the output amplitude of the specified source channel. The default unit is Vpp.
Parameter
Name
[<n>]
<Ampliude>
Explanation
You can use the
impedance.
Return
The query returns the amplitude in scientific notation, such as 1.0000000e+00.
Format
Example
:VOLTage 2
2-70
Type
Range
Discrete
{1|2}
Real
0 to 100
Type
Range
Discrete
{1|2}
Related to the output
impedance:
Real
HighZ: 20mVpp to 5Vpp
50Ω: 10mVpp to 2.5Vpp
[:SOURce[<n>]]:OUTPut[<n>]:IMPedance
Chapter 2 Command System
Default
If omitted, the operation is
performed on source 1 by
default
10
Default
If omitted, the operation is
performed on source 1 by
default
1Vpp