Chapter 2 Command System

:MASK:OUTPut

Syntax
:MASK:OUTPut <bool>
:MASK:OUTPut?
Description
Enable or disable the sound prompt when the failed waveforms are detected, or query the
status of the sound prompt.
Parameter
Name
<bool>
Explanation
Return
The query returns 0 or 1.
Format
Example
:MASK:OUTPut ON

:MASK:X

Syntax
:MASK:X <x>
:MASK:X?
Description
Set or query the horizontal adjustment parameter in the pass/fail test mask.
Parameter
Name
<x>
Explanation
The step is 0.02 within the range.
Return
The query returns the horizontal adjustment parameter in scientific notation.
Format
Example
:MASK:X 0.28
:MASK:X?

:MASK:Y

Syntax
:MASK:Y <y>
:MASK:Y?
Description
Set or query the vertical adjustment parameter in the pass/fail test mask.
Parameter
Name
<y>
Explanation
The step is 0.04 within the range.
Return
The query returns the vertical adjustment parameter in scientific notation.
Format
Example
:MASK:Y 0.36
:MASK:Y?
DS1000Z Programming Guide
Type
Bool
OFF: when failed waveforms are detected, there are display and output but the
beeper does not sound.
ON: when failed waveforms are detected, there are display and output and the
beeper sounds (not related to the on/off state of the sound).
Type
Range
Real
0.02 to 4
/*Set the horizontal adjustment parameter to 0.28div*/
/*The query returns 2.800000e-01*/
Type
Real
/*Set the vertical adjustment parameter to 0.36div*/
/*The query returns 3.600000e-01*/
Range
{{0|OFF}|{1|ON}}
Range
0.04 to 5.12
RIGOL
Default
0|OFF
Default
0.24
Default
0.48
2-49