Fig. 4: Dimensions of IS/IE sensors
2.5

Sensor cables

Cable marking:
The cables have quick disconnects at both ends. The plug at the control unit side is always
straight.
SCI20S-GG
SCI20S-GW
SCI20S-GG-TE
Applicable to all cables: Bending radius:
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector-series I20
bis SE75.wmf
with straight cable socket at the sensor
with right angle cable socket at the sensor
extension cable for sensor cable (also use as quick disconnect)
Cable diameter:
The sensor cable is an active component of the sensor technology.
Note
The technical data of the sensors is valid only if the cable specification is
met. A shielded cable must be used.
The cable length can be to up to 50 m. Following the rule "the shorter the
better" generally leads to better measuring results.
Manual
50 mm at fixed installation
100 mm at flexible installation
7.1 mm
Suitable for drag chains, oil-proof, PUR jacket
Superflex Tronic(C)PUR TP 4 x 2 x 0.25 mm²