B0003308 / 1.4 /
13.02.2013
7
Fault messages, causes and remedies
Pos: 35 /Doppelblech/Geräte/R1002/9 Fehlermeldungen/Fehlertabelle AI100 @ 0\mod_1184851156984_501.doc @ 4155 @
Message
Meaning
Value for Teach-In is not plausible
Error 1
(measurement value is smaller than 25
or larger than 960)
Value for external Teach-In is not
Error 2
plausible
(measurement value is smaller than 25
or larger than 960)
External Teach-In is not permitted
Error 3
(system is still in factory-set condition)
Pos: 36 /Kapitelübersicht/10. Wartung @ 0\mod_1121422080015_501.doc @ 514 @
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Manual
Double Sheet Detector R100 I100
for pairs of sensors
Fault messages, causes and remedies
Cause / Remedy
Sensor has no contact with the sheet
Sensor cable is cut off
Sensor type is not suitable
System might be defective
Sensor has no contact with the sheet
Sensor cable is cut off
Sensor type is not suitable
System might be defective
Factory settings have not been
overwritten – perform Teach-In via
operating keys once.
39