Error Messages
5
785
Specified arb waveform does not exist
The DATA:COPY command copies the waveform from volatile memory to the
specified name in non-volatile memory. Before executing the DATA:COPY
command, you must download the waveform using the DATA VOLATILE or
DATA:DAC VOLATILE command.
786
Not able to delete a built-in arb waveform
You cannot delete any of the five built-in waveforms: "EXP_RISE", "EXP_FALL",
"NEG_RAMP", "SINC", and "CARDIAC".
787
Not able to delete the currently selected active arb waveform
You cannot delete the arbitrary waveform that is currently being output (FUNC:USER
command).
788
Cannot copy to VOLATILE arb waveform
The DATA:COPY command copies the waveform from volatile memory to the
specified name in non-volatile memory. The source for the copy is always
"VOLATILE". You cannot copy from any other source and you cannot copy to
"VOLATILE".
800
Block length must be even
The function generator represents binary data as 16-bit integers, which are sent
as two bytes (DATA:DAC VOLATILE command).