-222
Data out of range;
burst period; value clipped to ...
This generic message indicates that the burst period has been limited to an upper
or lower boundary.
-222
Data out of range;
burst count; value clipped to ...
This generic message indicates that the burst count has been limited to an upper
or lower boundary.
-222
Data out of range;
burst period limited by length of burst; value clipped to lower limit
It is not possible to specify a burst period which is too short for the function
generator to output with the specified burst count and frequency (see below). If
the burst period is too short, the function generator will automatically adjust it as
needed to continuously
re-trigger the burst.
-222
Data out of range;
burst count limited by length of burst; value clipped to upper limit
If the Immediate trigger source is selected (TRIG:SOUR IMM command), the burst
count must be less than the product of the burst period and the waveform
frequency as shown below.
Keysight 33210A User's Guide
Burst Period >
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Waveform Frequency
Burst Count < Burst Period × Waveform Frequency
Burst Count
+ 200 ns
Error Messages