5
Error Messages
-221
Settings conflict;
pulse wid th increased d ue to large period
For a pulse waveform, the minimum pulse width is 40 ns for periods up to 10
seconds. For periods above 10 seconds, the minimum pulse width is greater. The
function generator has adjusted the pulse width to the new minimum determined
by the current period. See
information.
-221
Settings conflict;
edge time decreased d ue to pulse wid th
For a pulse waveform, the function generator will automatically adjust the
waveform parameters in the following order as needed to generate a valid pulse:
(1) edge time, (2) pulse width or duty cycle, and then (3) period.
In this case, the function generator has decreased the edge time to accommodate
the specified pulse width.
-221
Settings conflict;
edge time decreased d ue to pulse d uty cycle
For a pulse waveform, the function generator will automatically adjust the
waveform parameters in the following order as needed to generate a valid pulse:
(1) edge time, (2) pulse width or duty cycle, and then (3) period.
In this case, the function generator has decreased the edge time to accommodate
the specified pulse duty cycle.
306
Edge Time < 0.625 × Pulse Width
Edge Time < 0.625 × Period × Duty Cycle ÷ 100