■Setting positioning data
When using 2-axis circular interpolation control with sub point designation (ABS circular sub), set the following positioning
data.
: Always set, : Set as required, : Setting restricted, : Setting not required
Setting item
[Da.1]
Operation pattern
[Da.2]
Control method
[Da.3]
Acceleration time No.
[Da.4]
Deceleration time No.
[Da.6]
Positioning address/movement amount
[Da.7]
Arc address
[Da.8]
Command speed
[Da.9]
Dwell time/JUMP destination positioning data No.
[Da.10]
M code/Condition data No./Number of LOOP to LEND repetitions/Number of pitches
[Da.20]
Axis to be interpolated No.1
[Da.21]
Axis to be interpolated No.2
[Da.22]
Axis to be interpolated No.3
[Da.27]
M code ON signal output timing
[Da.28]
ABS direction in degrees
[Da.29]
Interpolation speed designation method
Refer to the following for information on the setting details.
Page 452 Positioning data
Set a value in "[Da.8] Command speed" so that the speed of each axis does not exceed the value in "[Pr.8]
Speed limit value". (The speed limit does not function for the speed calculated by the Motion module.)
3 MAJOR POSITIONING CONTROL
80
3.2 Setting the Positioning Data
Downloaded from
ManualsNet.com
search engine
Setting required/not
Setting required/not
required for the
required for the
reference axis
interpolation axis
(Set ABS circular sub.)

Advertisement

Table of Contents
loading

Table of Contents