[Md.108] Servo status1
This area stores the servo status1.
• READY ON: Indicates the ready ON/OFF.
• Servo ON: Indicates the servo ON/OFF.
• Control mode: Indicates the control mode of the servo amplifier.
• Gain switching: Turns ON during the gain switching.
• Fully closed loop control switching: Turns ON during the fully closed loop control.
• Servo alarm: Turns ON during the servo alarm.
• In-position: The dwell pulse turns ON within the servo parameter "in-position".
• Torque limit: Turns ON when the servo amplifier is having the torque restricted.
• Absolute position lost: Turns ON when the servo amplifier is lost the absolute position.
• Servo warning: Turns ON during the servo warning.
Buffer memory configuration
b15
b14
b13
b12
(11)
(10)
(9)
(8)
*1 The control modes are shown below.
b2
b3
0
0
1
0
0
1
Refresh cycle: Operation cycle
■Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 401 Axis monitor data
[Md.109] Regenerative load ratio/Optional data monitor output 1
• The rate of regenerative power to the allowable regenerative power is indicated as a percentage.
• When the regenerative option is used, the rate to the allowable regenerative power of the option is indicated.
(Buffer memory) %
• This area stores the content set in "[Pr.91] Optional data monitor: Data type setting 1" and "[Pr.591] Optional data monitor:
Data type expansion setting 1" at optional data monitor data type setting.
Refresh cycle: Operation cycle
■Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 401 Axis monitor data
12 DATA USED FOR POSITIONING CONTROL
504
12.7 Monitor Data
Downloaded from
ManualsNet.com
b11
b10
b9
b8
b7
b6
(7)
Control mode
Position control mode
Speed control
Torque control
• When the forced stop of controller and servo amplifier occurs, the servo warning is turned ON. When the
forced stop is reset, the servo warning is turned OFF.
• Confirm the status during continuous operation to torque control mode with "[Md.125] Servo status3".
search engine
b5
b4
b3
b2
b1
b0
(6)
(5)
(4)
(3)
(2)
(1)
Stored items
(1)
READY ON
(2)
Servo ON
*1
(3)
Control mode
(4)
(5)
Gain switching
(6)
Fully closed loop control switching
(7)
Servo alarm
(8)
In-position
(9)
Torque limit
(10)
Absolute position lost
(11)
Servo warning
Storage
value
0: OFF
1: ON