Block Start Data - Mitsubishi Electric MELSEC iQ-R Series User Manual

Programmable
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

12.5
Before explaining the block start data setting items [Da.11] to [Da.14], the configuration of the block start data is shown below.
The block start data stored in the buffer memory of the Motion module is the following configuration.
2nd point
1st point
b15
[Da.11] Shape
b15
[Da.13] Special start instruction
The following explains the block start data setting items [Da.11] to [Da.14]. (The buffer memory addresses shown are those of
the "1st point block start data (block No.7000)".)
*1
Block No.
Axis
7000
Axis 1
Maximum control axis No.
7001
Axis 1
Maximum control axis No.
7002
Axis 1
Maximum control axis No.
7003
Axis 1
Maximum control axis No.
7004
Axis 1
Maximum control axis No.
*1 Setting cannot be made when the "Pre-reading start function" is used. If you set any of Nos. 7000 to 7004 and perform the Pre-reading
start function, the error "Outside start No. range" (error code: 1AA3H)" will occur.
Refer to the following for details.
Page 270 Pre-reading start function
Downloaded from
ManualsNet.com

Block Start Data

50th point
Setting item
Setting item
Buffer memory
Setting item
address
b8b7
b0
22000+400n
[Da.12] Start data No.
b8b7
b0
22050+400n
[Da.14] Parameter
n: Axis No. - 1
• To perform a high-level positioning control using block start data, set a number between 7000 and 7004 to
"[Cd.3] Positioning start No." and use "[Cd.4] Positioning starting point No." to specify a point No. between 1
and 50, a position counted from the beginning of the block.
• The number between 7000 and 7004 specified here is called the "block No.".
• With the Motion module, up to 50 "block start data" points and up to 10 "condition data" items can be
assigned to each "block No.".
Block Start Data
Start block 0
Start block 1
Start block 2
Start block 3
Start block 4
search engine
Buffer memory
address
Buffer memory
address
22049+400n
22001+400n
22099+400n
22051+400n
Condition
Condition data (1 to 10)
Condition data (1 to 10)
Condition data (1 to 10)
Condition data (1 to 10)
Condition data (1 to 10)
Condition data (1 to 10)
Condition data (1 to 10)
Condition data (1 to 10)
Condition data (1 to 10)
Condition data (1 to 10)
12 DATA USED FOR POSITIONING CONTROL
●Up to 50 block start data points can be
set (stored) for each axis in the buffer
memory addresses shown on the left.
●Items in a single unit of block start
data are shown included in a bold frame.
●Each axis has five start blocks (block Nos. 0 to 4).
Buffer memory
Supports the settings
12.5 Block Start Data
12
Engineering
tool
Supports the
settings
469

Advertisement

Table of Contents
loading

Table of Contents