Precautions for control
• In manual control (JOG operation, inching operation, manual pulse generator operation) and speed-torque control, the stop
command processing for deceleration stop function is invalid.
• The stop command processing for deceleration stop function is valid when "0: Normal deceleration stop" is set in "[Pr.37]
Stop group 1 rapid stop selection" to "[Pr.39] Stop group 3 rapid stop selection" as the stopping method for stop cause
occurrence.
• The stop command processing for deceleration stop function is invalid when "1: Rapid stop" is set in "[Pr.37] Stop group 1
rapid stop selection" to "[Pr.39] Stop group 3 rapid stop selection". (A deceleration curve is re-processed starting from the
speed at stop cause occurrence until at a stop, according to "[Pr.36] Rapid stop deceleration time".) In the position control
(including position control of speed/position changeover control or position/speed changeover control) mode, positioning
may stop immediately depending on the stop cause occurrence timing and "[Pr.36] Rapid stop deceleration time" setting.
V
Deceleration stop
processing (automatic
deceleration) start
(Rapid stop in front of the specified positioning address)
Setting method
To use the "stop command processing for deceleration stop function", set the following control data in a program.
The set data are made valid as soon as they are written to the buffer memory. The PLC READY signal [Y0] is irrelevant.
Setting item
[Cd.42]
Stop command processing for
deceleration stop selection
Refer to the following for the setting details.
Page 512 Control Data
8 CONTROL SUB FUNCTIONS
276
8.7 Functions Related to Stop
Downloaded from
ManualsNet.com
Stop cause occurrence
(Rapid stop cause)
Deceleration curve according
to rapid stop deceleration time
Deceleration curve when
stop cause does not occur
Setting
value
search engine
V
Deceleration stop
processing (automatic
deceleration) start
t
(Immediate stop at the specified positioning address)
Setting details
Set the stop command processing for deceleration stop
function.
0: Deceleration curve re-processing
1: Deceleration curve continuation
Stop cause occurrence
(Rapid stop cause)
Deceleration curve according
to rapid stop deceleration time
Deceleration curve when
stop cause does not occur
Buffer memory address
Axis 1 to axis 16
5907
t