[Pr.123] Manual pulse generator speed limit value
Set the maximum speed during manual pulse generator operation.
■Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 399 Positioning parameters: Detailed parameters 2
[Pr.127] Speed limit value input selection at control mode switching
Set whether to input the value of "[Pr.8] Speed limit value" at speed-torque control mode switching.
The "Speed limit value input selection at control mode switching" is included in detailed parameters 2.
However, it will be valid at the leading edge (OFF to ON) of the PLC READY signal [Y0].
■Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 399 Positioning parameters: Detailed parameters 2
Downloaded from
ManualsNet.com
• The "Manual pulse generator speed limit value" is included in detailed parameters 2. However, it will be
valid at the leading edge (OFF to ON) of the PLC READY signal [Y0].
• Set the "Manual pulse generator speed limit value" to a value less than "[Pr.8] Speed limit value". If the
"speed limit value" is exceeded, the error "Manual pulse generator speed limit value error" (error code:
1BBAH) will occur.