2.1

Network Setting

This section explains the network configuration.
Devices
SECS/GEM communication software pre-installed model module
Host
Computer for configuration
Network setting for connection
Operating procedure
1.
Configure the network section of each device in the same manner.
A
B
192.168.3.
3
255.255.255.
0
SECS/GEM communication software
pre-installed model module
A: Network section
B: Host section
(1) Configure the same value.
(2) Configure different values.
2.
Configure the network settings of the personal computer using the "Internet Protocol Version 4 (TCP/IPv4) Properties"
screen.
(Example) Windows 7
 Select [Control Panel]  [Network and Internet]  [Network and Sharing Center]  [Change adapter settings].
 Select "Local Area Connection" and select [Properties] on the shortcut menu.
At the "Local Area Connection Properties" screen, choose "Internet Protocol Version 4 (TCP/IPv4)", and then click the
[Properties] button.
 The "Internet Protocol Version 4 (TCP/IPv4) Properties" screen appears.
Setting method
Configure the parameters using GX Works3 or the Setting/monitoring tools for the C
Controller module.
Configure the PC network.
Configure the PC network.
(1)
A
B
192.168.3.
15
255.255.255.
0
Host
(2)
A
B
192.168.3.
30
255.255.255.
0
Computer for configuration