Appendix 7 Secs/Gem Communication Software Unique Ack Code List - Mitsubishi Electric MELSEC iQ-R Series User Manual

C controller/c intelligent function module secs/gem communication software pre-installed model
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Appendix 7
This section shows the list of ACK codes.
Name
Item
Format
Code
ACKC5
10
DRACK
10
EAC
10
LIMITACK
10
LRACK
10
TIAACK
10
SECS/GEM communication software
unique ACK code list
Description
Value
E5-1107
Confirmation code,
0 = Agreement
1 byte
>0 = Error, cannot be comprehended
1 to 63: reserved
Definition report
0 = Agreement
agreement code,
1 = Denied, space insufficient
1 byte
2 = Denied, disabled format
3 = Denied, at least one RPTID is
already defined.
4 = Denied, not even one VID exists.
>4 = Other error
5 to 63: reserved
Equipment confirmation
0 = Agreement
code,
1= Denied, not even one variable
1 byte
exists.
2 = Denied, busy
3 = Denied, at least one variable is
outside the range
>3 = Other equipment inherent error
4 to 63: reserved
Confirmation code for
1 = LIMITID does not exist.
variable limit attribute
2=UPPERDB > LIMITMAX
setting,
3=LOWERDB < LIMITMIN
1 byte
4=UPPERDB < LOWERDB
5 = Clearly incorrect format for
UPPERDB or LOWERDB
6 = Cannot be interpreted as a
numerical value because it is an ASCII
value
7 = Limit definitions overlap for this
variable
>7 = Other equipment specific error
8 to 63: reserved
Link report confirmation
0 = Agreement
code,
1 = Denied, space insufficient
1 byte
2 = Denied, disabled format
3 = Denied, at least one CEID link is
already defined.
4 = Denied, not even one CEID exists.
5 = Denied, not even one RPTID
exists.
>5 = Other error
6 to 63: reserved
Equipment response
0 = Normal
code,
1 = Too many state variable IDs (SVID)
1 byte
2 = Trace not possible after this
3 = Invalid trace interval
>3 = Machine inherent error
4 to 63: reserved

Appendix 7 SECS/GEM communication software unique ACK code list

SECS/GEM communication
software inherent
1 = ALID does not exist
5 =RPTID value incorrect (RPTID=0)
6 = Excessive linkable VID for one
RPTID
4 = Batch conversion ECV value
exceeded
5 = Variable cannot be changed
6 = System error (register writing)
8 = Limit definition cannot be
registered
6 = Excessive linkable RPTID for one
CEID
4 = SV not registered
5 = SV incorrect format
6 = TRID value incorrect (TRID=0)
7 = Excessive reportable sample
number at one time
Applicati
on
S5F2, F4
S2F34
S2F16
S2F46
A
S2F36
S2F24
APPX
297

Advertisement

Table of Contents
loading

Table of Contents