Restrictions for setting the number of points (the number of words)
The SECS/GEM communication software has CA-SECS work areas.
A CA-SECS work area is an area for saving CA-SECS device assignment (I/O assignment) settings.
CA-SECS work areas are consumed by adding CA-SECS device assignment (I/O assignment) settings.
Settings that exceed the number of CA-SECS work areas will be invalid.
Set CA-SECS device assignment (I/O assignment) settings within the CA-SECS work area range.
Series
MELSEC-Q series
MELSEC iQ-R series
The following shows the correspondence between the number of points (the number of words) for the CA-SECS device
assignment (I/O assignment) and the number of consumed CA-SECS work areas.
• Bit device: One CA-SECS work area is consumed per 16 words.
• Word device: One CA-SECS work area is consumed regardless of the number of device points (the number of words).
The following table shows images of CA-SECS work areas to be used when setting CA-SECS device assignment (I/O
assignment).
• Usage example 1 of CA-SECS work areas
Setting
■MELSEC-Q series
■MELSEC iQ-R series
Number of CA-SECS work areas
16
14
Image of CA-SECS work areas
M0 to 255 (Points: 16 words)
CA-SECS work area 1
CA-SECS work area 1
M256 to 511 (Points: 16 words)
CA-SECS work area 2
M512 to 599 (Points: 3 words)
CA-SECS work area 3
M1024 to 1279 (Points: 16 words)
CA-SECS work area 4
D0 to 1023 (Points: 1024 words)
CA-SECS work area 5
ZR0 to 1023 (Points: 1024 words)
CA-SECS work area 6
CA-SECS work area 7
CA-SECS work area 8
CA-SECS work area 9
CA-SECS work area 10
CA-SECS work area 11
CA-SECS work area 12
CA-SECS work area 13
CA-SECS work area 14
CA-SECS work area 15
CA-SECS work area 16
In this example, all of the set devices can be used.
M0 to 255 (Points: 16 words)
CA-SECS work area 1
CA-SECS work area 1
M256 to 511 (Points: 16 words)
CA-SECS work area 2
M512 to 599 (Points: 3 words)
CA-SECS work area 3
M1024 to 1279 (Points: 16 words)
CA-SECS work area 4
D0 to 1023 (Points: 1024 words)
CA-SECS work area 5
ZR0 to 1023 (Points: 1024 words)
CA-SECS work area 6
CA-SECS work area 7
CA-SECS work area 8
CA-SECS work area 9
CA-SECS work area 10
CA-SECS work area 11
CA-SECS work area 12
CA-SECS work area 13
CA-SECS work area 14
In this example, all of the set devices can be used.
7 BASIC FUNCTIONS
83
7.6 Device Assignment