■Processing-stop message
The equipment stops current processing at the processing unit specified by the host.
The message has one parameter.
Message format
<HCS>
<L, 2>
1. ASCII <RCMD>
2. <L, 1>
1. <L, 2>
1. ASCII <CPNAME1>
2. U2 <CPVAL1>
■Board withdrawal message
The equipment withdraws the board of the processing unit specified by the host to the specified slot of the carrier of the
specified load port.
The message has three parameters.
Message format
<HCS>
<L, 2>
1. ASCII <RCMD>
2. <L, 3>
1. <L, 2>
1. ASCII <CPNAME1>
2. U2 <CPVAL1>
2. <L, 2>
1. ASCII <CPNAME2>
2. U2 <CPVAL2>
3. <L, 2>
1. ASCII <CPNAME3>
2. U2 <CPVAL3>
Item value
STOP
PNO
1 to 2
Item value
UNLOAD
PORT
1 to 2
SLOT
1 to 4
PNO
1 to 2
9 SECS/GEM COMMUNICATION SOFTWARE KNOWLEDGE
Notes
Processing-stop command
Number of parameters
Equipment processing unit number parameter
name
Equipment processing unit No.
Notes
Board retrieval command
Number of parameters
Load port number parameter name
Load port number
Slot number parameter name
Slot number
Equipment processing unit number parameter
name
Equipment processing unit No.