Operation Register List
No.
Name
1
Prev_Time
2
Next_Time
3
Prev_Page
4
Next_Page
5
Top_Line
6
End_Line
7
Jump_Data
8
Jump_Line
9
SECS_S_Mask
10
SECS_D_Mask
11
PLC_Mask
12
USER_Mask
13
WRAP
14
CLEAR
15
Info
16
Not used
*1 Turned OFF by the SECS/GEM communication software.
*2 Switched ON/OFF by the SECS/GEM communication software.
Display Register List
No.
Name
1
Log_Year
2
Log_Month
3
Log_Day
4
Log_Hour
5
Line_No
6
Not used
7
Log_Area
*1 Data format is unsigned BIN16.
*2 Data format is unsigned BIN32.
*3 Display by an ASCII string.
Description
ON = Move to the previous hour.
ON = Move to the next hour.
ON = Move to the previous page.
ON = Move to the next page.
ON = Move to the top line.
ON = Move to the end line.
ON = Move to the specified date and
time.
ON = Move to the specified line.
ON = Display the target log.
OFF = Do not display the target log.
ON = Wrap at the maximum number of
characters.
OFF = Do not wrap at the maximum
number of characters.
ON = Clear the screen.
ON: Operation error (when there is no
move-destination file)
OFF: Operation normal
Not used
Description
Enter the year of the log to be
displayed.
(YYYY: 0000 to 9999)
Enter the month of the log to be
displayed.
(MM: 01 to 12)
Enter the day of the log to be
displayed.
(DD: 01 to 31)
Enter the time of the log to be
displayed.
(HH: 00 to 23)
Enter the line number of the jump
destination.
Not used
Start register of the log display area.
Programmable Display Setting Operation
*1
Bit set
Bit invert
*1
Bit set
*2
Reference
Not used
Size
Programmable Display Setting Operation
(Word)
*1
1
Read/Write
1
1
1
*2
2
Read/Write
2
Not used
*3
5440
Read