Dynamic setting exclusion

This setting is used to enable host to notify Programmable Controller CPU that event report pertaining to the equipment etc. is
subjected to dynamic changes, and in order to enable Programmable Controller CPU to prohibit host from introducing
dynamic changes.
Window
[GEMData]  [Details]  [Dynamic Configuration Exclusion] tab
Displayed items
Item
Scenario
Enable
Processing Notification
Data Lock
Description
Select a scenario.
The following scenarios can be selected.
• S2F33: Specified report
• S2F35: link event report
• S2F37: enable/disable event report
• S2F45: variable limit attribute definition
Select this checkbox to enable dynamic configuration exclusion control of scenarios.
Configure the relay for the SECS/GEM communication software to notify the programmable controller
CPU that processing is occurring for each scenario.
To lock changes when a change notification of a dynamic setting is received from the host, the data lock
relay is used, and this relay is turned ON from the Programmable Controller CPU.
Lock cannot be enabled after receiving the change notification message from the host.
The lock should be turned ON in advance based on the equipment state.
Select the "ABORT" checkbox to return an abort message.
8 GEM COMPLIANT FUNCTIONS
8.17 Advanced Settings