Mitsubishi Electric MELSEC iQ-R Series User Manual page 157

C controller/c intelligent function module secs/gem communication software pre-installed model
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Item
SECS Log Setting
SECS Log Output
Output The Link Test
Frame Log
Programmable controller
log setting
Programmable controller
log output trigger
Collect The Detailed
PLC Log
Description
Select this checkbox to enable SECS log collection.
Select this checkbox to control the start or end of log collection by a trigger from the programmable
controller CPU.
By specifying the trigger relay, SECS log collection will be started when the specified trigger relay turns
ON and will be terminated when the trigger relay turns OFF.
If this item is not configured, SECS communication logs are always collected from when the SECS/
GEM communication software starts.
Select this checkbox to save the host link test log in the SECS communication log.
By specifying the trigger relay, the link test log with the host is output to the SECS communication log
when the specified trigger relay turns ON and the log collection of link tests will be ended when the
trigger relay turns OFF.
When this item is not configured, the link test log is not output.
Select this checkbox to enable Programmable controller log collection.
Select this checkbox to control the start or end of log collection by a trigger from the programmable
controller CPU.
By specifying the trigger relay, programmable controller log acquisition will be started when the
specified trigger relay turns ON and will be terminated when the trigger relay turns OFF.
When the detailed programmable controller CPU log will not be collected, only the status change of the
device assigned to the sending request trigger relay and reception notification trigger relay of the
message is recorded.
If this item is not configured, programmable controller logs are always output from when the SECS/
GEM communication software starts.
Select this checkbox to record the status change of all relays defined to the device assignment to the
programmable controller log.
By specifying the trigger relay, a detailed log is output to the programmable controller log when the
specified trigger relay turns ON and will be terminated when the trigger relay turns OFF.
When this item is not configured, the detailed programmable controller log is not output.
7 BASIC FUNCTIONS
155
7.17 Log Output