• MELSEC iQ-R series SECS/GEM communication software pre-installed model module
Method
Deleting an IP address setting file
Initializing a module
7 BASIC FUNCTIONS
134
7.13 IP Address Setting
Applicable condition
When setting ROM or SD as a
transfer destination of CA-SECS
When setting ROM as a transfer
destination of CA-SECS
When setting SD as a transfer
destination of CA-SECS
When setting ROM or SD as a
transfer destination of CA-SECS
Description
Copy the following file into the root of an SD card using a card reader.
(A SECS/GEM communication software installation folder)/RECOVERY/
STARTUP.CMD
Insert the SD card into a C intelligent function module and power the
module ON.
Check that 'CARD RDY' turns ON on the C intelligent function module.
When setting ROM as a transfer destination of CA-SECS
Specify an IP address set in the parameter settings of GX Works3 and delete
'/SD/STARTUP.CMD' of the module by FTP communication.
When setting SD as a transfer destination of CA-SECS
Select [Setting] [Update Module]. After that, specify an IP address set in the
parameter settings of GX Works3 and select the checkbox of "Applications
Install" to update the IP address.
Restart the module.
Set "Stop Script File Setting" for a operation mode of mode settings in the
parameter settings of GX Works3.
Write parameter settings to a module.
Restart the module.
Specify an IP address set in the parameter settings of GX Works3 and
delete '/ROM/CAS/IPADDR.txt' of the module by FTP communication.
Set "Online" for an operation mode in "Mode Settings" of parameter
settings in GX Works3.
Write parameter settings to a module.
Select [Setting] [Update Module] in a setting tool. Specify the IP address
set in GX Works3 parameter settings and select the checkbox of "Applications
Install" to update the IP address.
Restart the module.
Remove an SD card from a module and perform the procedure described in
'When setting ROM as a transfer destination of CA-SECS' under 'Applicable
condition.'
Initialize a module.
For details on the initialization, refer to the following:
MELSEC iQ-R C Intelligent Function Module User's Manual (Application)
After restarting the module, perform the procedure described in the following
section:
Page 16 PROCEDURE BEFORE OPERATION