Variables defined by default

The following section shows predefined variables of the SECS/GEM communication software.
These include variables independently defined by SECS/GEM communication software also.
Name
MDLN
SOFTREV
EstablishCommunication
sTimeout
DefaultCommunications
State
CommunicationsState
DefaultControlState
DefaultOfflineState
ControlState
ProcessPartsCount
ProcessChangePart
8 GEM COMPLIANT FUNCTIONS
216
8.11 Variable Setting
Classi
Description
ficatio
n
ECV
Module name
ECV
Software revision
ECV
Attempt Communication
establishment attempt timer
ECV
Default communication state
SV
Communication state
ECV
Default control state
ECV
Default state upon online
establishment failure
SV
Control state
ECV
No. of processing sections
DVVAL
Process state change
processing unit number
Format
E30
Variable value
stan
setting
dard
ASCII
Fixed value
6Byte
Can be set
ASCII
Fixed value
6Byte
Can be set
U2
Can be set
U1
Can be set
U1
Register notification
Can be set
U1
Fixed value
Can be set
U1
Fixed value
Can be set
U1
Register notification
Can be set
U1
Fixed value
Can be set
U1
Can be set
Notes
It is defined in system default settings.
It is used in S1F13 and S1F2.
It is defined in system default settings.
It is used in S1F13 and S1F2.
It is defined in communication state
model settings.
Default value: 10s (1 to 240)
It is defined in communication state
model settings.
0: DISABLED
1: ENABLED
It is defined in communication state
model settings.
1: Communication disabled (DISABLED)
2: Communication interrupted (WAIT
CRA/WAIT CR FROM HOST)
3: Communication interrupted (WAIT
DELAY/WAIT CR FROM HOST
4: Communication in progress
(COMMUNICATING)
Default value: 1
It is defined in control state model
settings.
1: equipment offline
2: transition to online in progress
3: host offline
4: Online
Default value: 1
It is defined in control state model
settings.
1: equipment offline
3: host offline
Default value: 1
It is defined in control state model
settings.
1: equipment offline
2: transition to online in progress
3: host offline
4: online local
5: online remote
Default value: 1
It is defined in processing state model
settings.
Default value: 1 (0 to 99)
It is defined in processing state model
settings.
Programmable Controller CPU notifies
the processing unit number whose state
has been changed.