State Change
Window
[GEMFunction]  [Control State]  [State Change] tab
Displayed items
Item
ON-LINE/OFF-LINE
Trigger hold time
REMOTE/LOCAL
Trigger hold time
Control
Window
[GEMFunction]  [Control State]  [Control] tab
Description
Set the relay used to notify the SECS/GEM communication software about the transition to ON-LINE/
OFF-LINE from the Programmable Controller CPU.
When this setting is enabled, turn the trigger ON to configure an ON-LINE state and turn the trigger
OFF to configure an OFF-LINE state.
An ON-LINE/OFF-LINE trigger results when the ON-LINE/OFF-LINE relay is held for the configured
time.
If the "Not Monitored" checkbox is selected, ON-LINE/OFF-LINE trigger processing is carried out
without hold monitoring.
Configure the relay to notify the SECS/GEM communication software from the programmable controller
CPU of a REMOTE/LOCAL switch.
When this setting is enabled, turn the trigger ON to configure a REMOTE state and turn the trigger OFF
to configure a LOCAL state.
A REMOTE/LOCAL trigger results when the REMOTE/LOCAL relay is held for the configured time.
If the "Not Monitored" checkbox is selected, REMOTE/LOCAL trigger processing is carried out without
hold monitoring.
8 GEM COMPLIANT FUNCTIONS
8.5 Control State Model Management
8
187