Alarm Definition

Series
MELSEC-Q series
MELSEC iQ-R series
Edit the alarm definition.
Window
Select an alarm in the "Alarm List" screen, right-click  shortcut menu [Modify]
Displayed items
Item
Enable Alarm
Alarm No.
ALID
ALCD
Hexadecimal
ALTX
Comment
Link The Event
Alarm
Occurrence
Alarm Cancel
8 GEM COMPLIANT FUNCTIONS
194
8.7 Alarm Definition (GEM / GEM advanced version)
SECS/GEM communication software
Non-GEM version
Description
Select this checkbox to use alarms.
The alarm enabled status may be switched by instruction from the host.
Configure the number that corresponds to the prescribed alarm state register. (Start from 1)
Configure the content of the alarm ID <ALID > related to the alarm number.
Configure the content of the alarm code <ALCD > related to the alarm number.
Select this checkbox to configure ALCD in hexadecimal.
If this checkbox is cleared, the notation is decimal.
Configure the content of the alarm text <ALTX > related to the alarm number.
Configure the alarm comment.
The content of the comment is not sent as an alarm message.
Select an event report to send when an alarm has occurred.
Select whether to send an event report when an alarm was cancelled.
GEM version
GEM advanced version