SECS items

Configure the SECS-data item-format used by the SECS/GEM communication software.
Window
[GEMData]  [Details]  [SECS Item] tab
Displayed items
Item
Item
Default data type of SECS items
The following table shows default formats by item.
Item
VID
UNITS
ECID
ECNAME
SVID
SVNAME
CEID
RPTID
*1
CEED
DATAID
DATALENGTH
TRID
DSPER
TOTSMP
REPGSZ
SMPLN
LIMITID
MEXP
*1 In the software version 1.35M or later, a true value for a CEED item (BOOL type) is other than 0.
8 GEM COMPLIANT FUNCTIONS
234
8.17 Advanced Settings
Description
Select an item to be defined.
Data Type
Select the data type of the item.
Data Counts
Configure the data count of the item.
Variable Length
Select this checkbox to configure the data count to a variable length.
Configuring a variable length enables 0 length reception.
Description
Variable ID
Unit
Equipment constant ID
Equipment constant name
State variable ID
State variable ID
Acquired event ID
Report ID
Trace YES/NO code
Data ID
Total no. of data bytes
Trace request ID
Data acquisition time
Total sample count
Report group size
Sample number
Limit ID
Message SxFy to be received
Data type
U2
ASCII 16Byte
U2
ASCII 32Byte
U2
ASCII 32Byte
U2
U2
BOOL
U2
U2
U2
ASCII 8Byte
U2
U2
U2
BIN
ASCII 6Byte