Mitsubishi Electric MELSEC iQ-R Series User Manual page 220

C controller/c intelligent function module secs/gem communication software pre-installed model
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Name
SpoolingState
SpoolCountActual
SPoolCountTotal
SpoolFullTime
SpoolStartTime
Clock
TimeFormat
ChangeECID
HostChangeECID
LimitsSamplingInterval
EventLimit
LimitVariable
TransitionType
EventsEnabled
PPChangeName
PPChangeStatus
PPExecName
8 GEM COMPLIANT FUNCTIONS
218
8.11 Variable Setting
Classi
Description
ficatio
n
SV
Spooling state
SV
No. of actual spool messages
SV
No. of cumulative spool
messages
SV
Spool full time
SV
Spool start-up time
SV
Current time within
equipment
ECV
Time data format
DVVAL
Changed Equipment
constant ID
DVVAL
Equipment constant ID
changed by host
ECV
Sampling cycle for limit
monitoring
DVVAL
Limit/Cross limit ID
DVVAL
VID that exceeded limit
monitoring area
DVVAL
Transition direction of the
monitoring scope of the
occurred limits
SV
List of events enabled for
report
DVVAL
Process program name
changed by operator
DVVAL
Process program changed
event contents
SV
Process program ID of the
selected Process program
Format
E30
Variable value
stan
setting
dard
BIN
Register notification
Can be set
U4
Cannot be set
U4
Cannot be set
ASCII
Cannot be set
ASCII
Cannot be set
ASCII
Can be set
16/12Byte
U1
Register reference
Can be set
Register notification
Can be set
U4
Fixed value
Can be set
Cannot be set
Cannot be set
BIN
Cannot be set
LIST
Cannot be set
Cannot be set
U1
Cannot be set
LIST
Cannot be set
Notes
It is defined in spool settings.
00H: spool stopped
01H: active, no input, empty spool
02H: active, spool transmission, empty
spool
03H: active, purge spool, empty spool
81H: active, no output, full spool
82H: active, spool transmission, full spool
83H=active, purge spool, full spool
It is managed within SECS/GEM
communication software (0 to
4294967295).
It is managed within SECS/GEM
communication software (0 to
4294967295).
Format: YYYYMMDDhhmmsscc
(Compliant with TimeFormat)
Format: YYYYMMDDhhmmsscc
(Compliant with TimeFormat)
Time data of the SECS/GEM
communication software pre-installed
model module
(Format: YYYYMMDDhhmmsscc)
It is defined in clock settings
0: 12 byte format
1: 16 byte format
Default value: 16 byte
The format is the same as that of
Equipment constant ID
The format is the same as that of
Equipment constant ID
It is defined in limit monitoring settings.
Default value: 5000ms (1000 to
4294967295)
It is managed within SECS/GEM
communication software.
The format is the same as that of limit ID
(list structure in case of multiple
occurrence)
It is managed within SECS/GEM
communication software.
The format is the same as that of variable
ID
It is managed within SECS/GEM
communication software.
0: transition from downward direction to
upward direction
1: transition from upward direction to
downward direction
It is managed within SECS/GEM
communication software.
It is managed within SECS/GEM
communication software.
The format is the same as that of Process
program ID
It is managed within SECS/GEM
communication software.
1: created
2: edited
3: deleted
4 to 63: reserved