Appendix 5 Communication Specifications Check Sheet - Mitsubishi Electric MELSEC iQ-R Series User Manual

C controller/c intelligent function module secs/gem communication software pre-installed model
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Appendix 5
The check sheet shows what to check in definition of SECS communication. The check sheet is useful for checking the
specifications.
Setting item
Communication port
Device ID
SECS- setting
Mode
Transmission speed [bps]
T1 [sec] (0.1 to 10)
T2 [sec] (0.2 to 25)
T3 [sec] (1 to 120)
T4 [sec] (1 to 120)
HSMS setting
Host IP address
Own station IP address
Host port number
Own station port number
Mode
T3 [sec] (1 to 120)
T5 [sec] (1 to 240)
T6 [sec] (1 to 240)
T7 [sec] (1 to 240)
T8 [sec] (1 to 120)
Link Test timer [sec] (1 to 65535)
Number of retries after line disconnection
(Endless retries / specified number of times)
Line disconnection from own station
Sending-side interleaving (multi-open transaction)
Interleaving for reception (open multi-transactions)
Variable length lists
Variable length items
Switch into offline status upon disconnection
Spooling
Multi-block transmission permission by host
SxF0 transmission
SxF0 reception
S9F1/F3/F5/F9/F11 transmission
S9F7(item data error) transmission
S9F13 transmission
SECS communication log storage
Communication Specifications Check
Sheet
Setting content
SECS-/HSMS
Master / Slave
Passive / Active
Endless /
times
Enable / Disable
Enable / Disable
Enable / Disable
Enable / Disable
Enable / Disable
Enable / Disable
Enable / Disable
Enable / Disable
Enable / Disable
Enable / Disable
Automatic transmission
Enable / Disable
Enable / Disable
Enable / Disable
Notes
Inter-character time-out
Protocol time-out
Response time-out
Inter-block time-out
Response time-out
Connection separation time-out
Control transaction time-out
Not Selected time-out
Inter-character time-out for network
Number of multi-transaction queues for PLC
transmission
Number of multi-transaction queues for PLC
reception
Set the maximum value for the number of
data sets.
If Enable is set, a scenario for permission
frame must be defined.
A scenario for illogical data processing must
be defined.
If Enable is set, a scenario must be defined
for this purpose.