Interval unit and configuration range
The following table shows the configurable range of each interval unit.
Interval unit
*1
msec
*1
sec
*1
min
*1
hour
*1 In addition to the units described above, MELSEC-Q series setting tools with GEM version and GEM advanced version can set "msec-
1," "sec-1," "min-1," and "hour-1." These units do not perform the first cyclic sending.
Precautions
■T9 timer monitor setting of message information
When an error has occurred due to T9 timer monitoring, a T9 timer timeout notification is sent using the trigger relay from the
SECS/GEM communication software.
For details on SECS error notifications, refer to the following:
Page 107 SECS error notification setting
When it is necessary to notify the host of a T9 timer occurrence by S9F13, a new transaction must be defined by the user.
For details on S9F13, refer to the following:
Page 290 System error (S9Fx)
A primary receipt message is necessary for T9 monitoring. Always configure the reception notification trigger for this primary
receipt message.
■When the reception notification trigger is on
The following events occur.
Item
S9 and F3 occurrence
S9 and F5 occurrence
Abort Return
millisecond
Second
Minute
Time
Description
S9 and F3 occur when there is no other definition configured that has the same stream as the message.
S9 and F3 also occur when no reception notification trigger has been configured.
S9 and F5 occur when there is one receipt definition or more with the same stream as the corresponding message,
and there is no definition that has the same transaction.
S9 and F3 also occur when no reception notification trigger has been configured.
Abort return occurs when there is one reception definition or more that has the same stream and function as the
corresponding message.
In such a case, an error log indicating that the reception notification trigger was not configured is output to the SECS
log for primary messages. While the operation ends normally without issuing any notifications for secondary
messages, data is not stored in the register.
Setting range
Fixed Value
1000 to 86400000
1 to 86400
1 to 1440
1 to 24
Registers Used
1000 to 65535
1 to 65535
1 to 1440
1 to 24
7 BASIC FUNCTIONS
7.4 Transaction List
7
67