Control state model setting

Configure the details of the control state model.
Default
Window
[GEMFunction]  [Control State]  [Default] tab
Displayed items
Item
Default Control State
Default State At The Time of On-Line
Trial Failure
State notification
Window
[GEMFunction]  [Control State]  [State Notification] tab
Displayed items
Item
Control State Notification
Interlock Relay
8 GEM COMPLIANT FUNCTIONS
186
8.5 Control State Model Management
Description
Select the control state of the SECS/GEM communication software when the power is turned ON.
This cannot be changed from the Programmable Controller CPU.
This setting is reflected in the equipment variable DefaultControlState.
Select the default state when online transition fails.
This cannot be changed from the Programmable Controller CPU.
This setting is reflected in the equipment variable DefaultOfflineState.
Description
Set the register used by the SECS/GEM communication software to notify the current state of the control state model
to the Programmable Controller CPU.
This value is the state variable ControlState.
For more details of values, refer to the following:
Page 216 Variables defined by default
To lock transition of the control state, use an interlock relay to switch this relay ON from the programmable controller
CPU.