Mitsubishi Electric MELSEC iQ-R Series User Manual page 79

C controller/c intelligent function module secs/gem communication software pre-installed model
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Precautions
Configure register settings on the programmable controller CPU management side or the CA-SECS device assignment (I/O
assignment) section.
SECS-I configuration
The following section shows the SECS- parameter values stored to registers.
Item
Device ID
Setting Request Trig
SECS-
Serial Port
Master/Slave
Baud rate [bps]
Number Of Retries
Serial Setting
Timer Setting
HSMS settings
The following section shows the HSMS parameter values stored to registers.
Item
Device ID
Setting Request Trig
HSMS
Active/Passive
IP Address (Local)
IP Address (Remote)
IP Port (Local)
IP Port (Remote)
Timer Setting
Setting value
0 to 32767
Trigger relay to apply setting information.
"1" only.
• 0: Master
• 1: Slave
9600, 14400, 19200, 38400, 57600, and 115200 only
(Only 2 consecutive registers are used.)
0 to 31
Data Length
• 7: B7
• 8: B8
Parity
• 0: PN
• 1: P0
• 2: PE
Stop Bit
• 1: S1
• 2: S2
Flow Control
• 0: NON
• 1: XON
• 2: RTS
T1
100 to 10000 (increments of 100)
T2
200 to 25000 (increments of 200)
T3
1 to 120 (increments of 1)
T4
1 to 120 (increments of 1)
Setting value
0 to 32767
Trigger relay to apply setting information.
• 0: Active
• 1: Passive
(0 to 255)
(Four consecutive registers are used.)
(0 to 255)
(Four consecutive registers are used.)
1 to 65535
1 to 65535
Link Test Timer
1 to 65535
T3
1 to 120 (increments of 1)
T5
1 to 240 (increments of 1)
T6
1 to 240 (increments of 1)
T7
1 to 240 (increments of 1)
T8
1 to 120 (increments of 1)
7 BASIC FUNCTIONS
7.5 Communication Setting
7
77