■When changing the IP address of a MELSEC-Q series SECS/GEM communication software
pre-installed model module
When changing the IP address using this function, CCPU parameters managed by the Setting/monitoring tools for the C
Controller module are overwritten.
Therefore, when changing the IP address with this function and reading it from the module using the Setting/monitoring tools
for the C Controller module, the IP address that is changed by this function is read.
■When changing the IP address of a MELSEC iQ-R series SECS/GEM communication software
pre-installed model module
When changing the IP address of MELSEC iQ-R series SECS/GEM communication software pre-installed model module by
using this function, the module operates with the IP address set in GX Works3 from when the power is turned ON to when
SECS/GEM communication software is started.
In addition, when configuring the IP address of the module by using this function, 'IP address configuration file' remains in the
standard ROM.
Therefore, IP address settings from GX Works3 to the MELSEC iQ-R series SECS/GEM communication software pre-
installed model module are not effective when the SECS/GEM communication software is running.
■Methods for clearing an IP address set by the IP address changing function
The following shows the methods for clearing an IP address set for a module using this function.
Perform any of the following methods:
• MELSEC-Q series SECS/GEM communication software pre-installed model module
Method
Setting an IP address again using the
Setting/monitoring tools for the C
Controller module
Initializing a module
Description
Set the IP address of a module again using the Setting/monitoring tools for the C Controller module.
After that, restart the module.
For details on the setting method, refer to the following:
MELSEC-Q C Controller Module User's Manual
C Controller Module User's Manual (Hardware Design, Function Explanation)
Initialize a module.
For details on the initialization, refer to the following:
MELSEC-Q C Controller Module User's Manual
C Controller Module User's Manual (Hardware Design, Function Explanation)
After restarting the module, perform the procedure described in the following section:
Page 16 PROCEDURE BEFORE OPERATION