Item
Abort Frame Reception
Abort Frame Sending
Sending failure
PLC Handshake Failure
T3 Timer Timeout
T9 Timer Timeout
*1
T1 Timer Timeout
*1
T2 Timer Timeout
*1
T4 Timer Timeout
*1
Scenario Interruption
Trigger Keep Time
Handshake
Communication error
*1 Can be configured for only the MELSEC-Q series SECS/GEM communication software pre-installed model module.
7 BASIC FUNCTIONS
108
7.7 Option Setting
Description
Configure the relay to notify the programmable controller CPU that the SECS/GEM communication
software has received an abort message.
Configure the relay to notify the programmable controller CPU that an abort message has been sent
from the SECS/GEM communication software.
Configure the relay to notify the programmable controller CPU that a data sending failure has occurred
from the SECS/GEM communication software.
Configure the relay to notify the programmable controller CPU that a handshake link with the
programmable controller CPU failed during data receipt.
Configure the relay to notify the programmable controller CPU that a response timeout occurred with
the host.
Notice Cancel By
Configure the relay to notify the ladder program that the T3 timer is canceled for a transaction in a
Disconnection/Offline
secondary message standby state due to a line disconnection or offline transition.
Configure the relay to notify the programmable controller CPU that a timeout of T9 timer management
occurred.
For details on the T9 timer, refer to the following:
Page 65 Message information
Configure the relay to notify the programmable controller CPU that a timeout occurred between
characters during reception from the host.
Configure the relay to notify the programmable controller CPU that a protocol timeout occurred with the
host.
Configure the relay to notify the programmable controller CPU that a timeout occurred between
message blocks during communication with the host.
Configure the relay to notify the programmable controller CPU that the scenario execution was
interrupted for some reason.
Configure the time to keep the configured notification relay.
Select this checkbox to link handshakes between the programmable controller CPU and SECS/GEM
communication software pre-installed model module with regard to SECS error notification.
When this checkbox is selected, the specified relay is monitored for handshaking. Note that
programmable controller CPU handshaking fails unless the specified relay is turned OFF by the
programmable controller CPU within the time defined by the PLC response monitoring timer.
For details on the PLC Response Monitoring Timer, refer to the following:
Page 86 Control
Frame
Configure the register to write the number of the Stream Function that had a transmission error.
The Stream number is written to the start register and the Function number is written into the next
register.
Trigger
Configure the register to write the type and number of the trigger relay that had a transmission error.
The defined register is the first register, and the next register will also be used for registration.
The device type is written to the start register and the device number is written into the next register.
The following section shows the values to be written as device types.
• Device type is M: 4
• Device type is B: 23